Mei Q. Wu and Colin G. Gordon
The commonly used recirculation air systems for microelectronics cleanrooms are described in this paper. The sound attenuation along the air flow paths are discussed along with noise control concerns. Also presented are the typical sound pressure levels measured in operating cleanrooms.
Reprinted from Proceedings of the 16th International Congress on Acoustics, p. 769-770, (1998)